Filter Results By:

Products

Applications

Manufacturers

Device Under Test

a specific purpose component or module check; ex. substantial component of a PCB.

See Also: DUT, Unit Under Test, EUT


Showing results: 316 - 317 of 317 items found.

  • PCI Express® 4.0 Receiver Test Automation Software (GRL-PCIE4-RXA)

    Granite River Labs Inc.

    PCI Express® 4.0 Receiver Test Automation Software Suite (GRL-PCIE4-RXA) provides an automated, simple and efficient way to test your 4.0 designs using the Anritsu MP1900A with any Tektronix and Keysight Real-Time Oscilloscope oscilloscope. The GRL-PCIE4-RXA Test Suite features two components that can be ordered separately or bundled together. GRL-PCIE4-BASE-RXA is used for testing your PCIe® 4.0 Receiver to the Base (ASIC) Specification, while GRL-PCIE4-CEM-RXA is used for testing end products to the PCIe® 4.0 CEM (Card Electro-Mechanical) Specification. GRL-PCIE4-RXA provides a simple user interface to automate complex PCIe testing. The software runs on Windows 7 or higher oscilloscope or any PC OS, and significantly reduces equipment calibration and test time. For Base Specification testing, GRL software uses the industry-standard Seasim statistical data eye simulator to establish the calibrated test channel DDJ. The final calibrated eye diagram uses both Seasim and SigTest software to arrive at the final stressed eye diagram. Receiver jitter tolerance and margin testing can then be performed on the device under test. For CEM Spec testing, GRL software uses VNA method for Channel measurement and SigTest for all other stressed eye impairments. Jitter Tolerance and Margin Testing is offered in both BASE and CEM software versions of the software, while The CEM version provides all the tests required by the PCIe® 4.0 CEM CTS. Transmitter testing is also available using GRL-PCIE34-TXP1 Software and Controller. If ordered with with GRL-PCIE4-RXA Receiver test software, all PCIe® 4.0 CTS CEM tests (Transmitter and Receiver) can be performed on the MP1900 and any vendor’s Real-Time Oscilloscope using GRL’s automation framework without the need for vendor specific software tools.

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.

Get Help